- Add scripts/agent.py and references/api-reference.md to all remaining skills - Update all 648 LICENSE files: copyright now reads 'Mahipal' - Add implementing-security-monitoring-with-datadog (new skill with full anatomy) - All 649 skills now have: SKILL.md, LICENSE, scripts/agent.py, references/api-reference.md
This commit is contained in:
@@ -0,0 +1,86 @@
|
||||
# SCADA HMI Security Assessment - API Reference
|
||||
|
||||
## SCADA Protocol Ports
|
||||
|
||||
| Port | Protocol | Description |
|
||||
|------|----------|-------------|
|
||||
| 102 | S7comm | Siemens S7 PLC communication |
|
||||
| 502 | Modbus TCP | Industrial automation protocol |
|
||||
| 2222 | EtherNet/IP | Allen-Bradley, Rockwell |
|
||||
| 4840 | OPC UA | Open Platform Communications Unified Architecture |
|
||||
| 20000 | DNP3 | Distributed Network Protocol |
|
||||
| 47808 | BACnet | Building Automation and Control |
|
||||
|
||||
## Port Scanning (socket stdlib)
|
||||
|
||||
```python
|
||||
import socket
|
||||
sock = socket.socket(socket.AF_INET, socket.SOCK_STREAM)
|
||||
sock.settimeout(2.0)
|
||||
result = sock.connect_ex((target, port)) # 0 = open
|
||||
sock.close()
|
||||
```
|
||||
|
||||
## pyshark for Protocol Analysis
|
||||
|
||||
```python
|
||||
import pyshark
|
||||
cap = pyshark.FileCapture("traffic.pcap")
|
||||
for pkt in cap:
|
||||
for layer in pkt.layers:
|
||||
print(layer.layer_name) # modbus, s7comm, dnp3, etc.
|
||||
cap.close()
|
||||
```
|
||||
|
||||
### Insecure SCADA Protocols
|
||||
These protocols lack built-in encryption and authentication:
|
||||
- **Modbus TCP** - No auth, no encryption, commands in plaintext
|
||||
- **S7comm** - No auth (pre-V4), no encryption
|
||||
- **DNP3** - Optional Secure Authentication (SA), rarely deployed
|
||||
- **BACnet** - No native security mechanisms
|
||||
- **EtherNet/IP** - No encryption, device enumeration possible
|
||||
|
||||
## HMI Configuration Checks
|
||||
|
||||
| Check | Severity | Description |
|
||||
|-------|----------|-------------|
|
||||
| Authentication disabled | Critical | HMI allows anonymous access |
|
||||
| No session timeout | High | Sessions persist indefinitely |
|
||||
| TLS disabled | High | Communications in plaintext |
|
||||
| Remote access without VPN | Critical | HMI exposed without tunnel |
|
||||
| No RBAC | High | Single role or no access control |
|
||||
| Default credentials | Critical | Factory-default username/password |
|
||||
|
||||
## Common Default Credentials
|
||||
|
||||
| Username | Password | Platform |
|
||||
|----------|----------|----------|
|
||||
| admin | admin | Generic HMI |
|
||||
| admin | 1234 | Siemens WinCC |
|
||||
| operator | operator | Wonderware |
|
||||
| engineer | engineer | GE iFIX |
|
||||
| guest | guest | Various |
|
||||
|
||||
## ICS Security Standards
|
||||
|
||||
- **IEC 62443** - Industrial communication network security
|
||||
- **NIST SP 800-82** - Guide to ICS Security
|
||||
- **NERC CIP** - Critical Infrastructure Protection (power grid)
|
||||
|
||||
## Output Schema
|
||||
|
||||
```json
|
||||
{
|
||||
"report": "scada_hmi_security_assessment",
|
||||
"target": "192.168.1.100",
|
||||
"total_findings": 6,
|
||||
"severity_summary": {"critical": 2, "high": 3, "medium": 1},
|
||||
"findings": [{"type": "open_scada_port", "severity": "high"}]
|
||||
}
|
||||
```
|
||||
|
||||
## CLI Usage
|
||||
|
||||
```bash
|
||||
python agent.py --target 192.168.1.100 --pcap traffic.pcap --config hmi.json --output report.json
|
||||
```
|
||||
Reference in New Issue