name: performing-ot-network-security-assessment
|
|
description: >
|
|
This skill covers conducting comprehensive security assessments of Operational
|
|
Technology (OT) networks including SCADA systems, DCS architectures, and industrial
|
|
control system communication paths. It addresses the Purdue Reference Model layers,
|
|
identifies IT/OT convergence risks, evaluates firewall rules between zones, and
|
|
maps industrial protocol traffic (Modbus, DNP3, OPC UA, EtherNet/IP) to detect
|
|
misconfigurations, unauthorized connections, and attack surfaces in critical infrastructure.
|
|
domain: cybersecurity
|
|
subdomain: ot-ics-security
|
|
tags: [ot-security, ics, scada, industrial-control, iec62443, network-assessment]
|
|
version: 1.0.0
|
|
author: mahipal
|
|
license: MIT
|
|
---
|
|
|
|
# Performing OT Network Security Assessment
|
|
|
|
## When to Use
|
|
|
|
- When conducting an initial security baseline of an OT/ICS environment for a new client
|
|
- When evaluating the security posture of a facility after an IT/OT convergence initiative
|
|
- When preparing for IEC 62443 or NERC CIP compliance audits
|
|
- When assessing risk following a merger or acquisition involving industrial facilities
|
|
- When investigating whether an OT network has been compromised or has unmonitored pathways to corporate IT
|
|
|
|
**Do not use** for IT-only network assessments without OT components, for application-layer vulnerability scanning of IT web applications (see performing-web-app-penetration-test), or for active exploitation of live OT systems without explicit authorization and safety controls in place.
|
|
|
|
## Prerequisites
|
|
|
|
- Written authorization from the asset owner and operations management for all assessment activities
|
|
- Understanding of the Purdue Reference Model and IEC 62443 zone/conduit architecture
|
|
- Passive network monitoring tools (Nozomi Guardian, Dragos Platform, or Wireshark with industrial protocol dissectors)
|
|
- Access to network diagrams, firewall rule sets, and asset inventories (or the ability to perform passive discovery)
|
|
- Safety briefing on the physical processes controlled by the OT systems under assessment
|
|
|
|
## Workflow
|
|
|
|
### Step 1: Establish Assessment Scope and Safety Boundaries
|
|
|
|
Define the scope based on the Purdue Reference Model levels and identify safety-critical systems that must not be actively scanned. OT assessments differ fundamentally from IT assessments because active scanning can crash PLCs, disrupt safety instrumented systems (SIS), and cause physical harm.
|
|
|
|
```yaml
|
|
# OT Assessment Scope Definition
|
|
assessment:
|
|
facility: "Chemical Processing Plant - Site Alpha"
|
|
purdue_levels_in_scope:
|
|
- level_0: "Physical process sensors and actuators (passive observation only)"
|
|
- level_1: "PLCs, RTUs, safety controllers (passive only, no active scanning)"
|
|
- level_2: "HMI stations, engineering workstations, historian (limited active with approval)"
|
|
- level_3: "Site operations - OPC servers, application servers (active scanning permitted)"
|
|
- level_3_5: "DMZ - data diodes, jump servers (active scanning permitted)"
|
|
- level_4: "Enterprise IT connecting to OT (active scanning permitted)"
|
|
|
|
safety_exclusions:
|
|
- "Safety Instrumented Systems (SIS) - Triconex controllers"
|
|
- "Emergency Shutdown (ESD) systems"
|
|
- "Fire and Gas detection systems"
|
|
- "Any Level 0/1 device during active production"
|
|
|
|
authorized_activities:
|
|
passive:
|
|
- "Network traffic capture and analysis via SPAN ports"
|
|
- "Industrial protocol deep packet inspection"
|
|
- "Wireless spectrum analysis"
|
|
- "Physical walkthrough and visual inspection"
|
|
active_with_approval:
|
|
- "Targeted Nmap scans of Level 2-4 systems during maintenance windows"
|
|
- "Authentication testing on HMI and engineering workstations"
|
|
- "Firewall rule verification between zones"
|
|
prohibited:
|
|
- "Active scanning of PLCs, RTUs, or SIS controllers"
|
|
- "Fuzzing industrial protocols on live systems"
|
|
- "Modifying PLC logic or firmware"
|
|
```
|
|
|
|
### Step 2: Perform Passive Network Discovery and Asset Inventory
|
|
|
|
Deploy passive monitoring to map all devices, communication flows, and protocols on the OT network without sending any traffic that could disrupt operations.
|
|
|
|
```python
|
|
#!/usr/bin/env python3
|
|
"""OT Network Passive Discovery and Asset Inventory Builder.
|
|
|
|
Uses pcap captures from SPAN ports to identify OT assets, protocols,
|
|
and communication patterns without active scanning.
|
|
"""
|
|
|
|
import json
|
|
import sys
|
|
from collections import defaultdict
|
|
from datetime import datetime
|
|
|
|
try:
|
|
from scapy.all import rdpcap, IP, TCP, UDP
|
|
from scapy.contrib.modbus import ModbusADURequest, ModbusADUResponse
|
|
except ImportError:
|
|
print("Install scapy: pip install scapy")
|
|
sys.exit(1)
|
|
|
|
# Industrial protocol port mappings
|
|
OT_PROTOCOL_PORTS = {
|
|
502: "Modbus/TCP",
|
|
102: "S7comm (Siemens)",
|
|
44818: "EtherNet/IP (CIP)",
|
|
2222: "EtherNet/IP (implicit)",
|
|
4840: "OPC UA",
|
|
20000: "DNP3",
|
|
47808: "BACnet",
|
|
1911: "Niagara Fox",
|
|
789: "Crimson v3 (Red Lion)",
|
|
2404: "IEC 60870-5-104",
|
|
18245: "GE SRTP",
|
|
5094: "HART-IP",
|
|
}
|
|
|
|
PURDUE_LEVEL_RANGES = {
|
|
"Level 0-1 (Field Devices)": ["10.10.0.0/16", "192.168.10.0/24"],
|
|
"Level 2 (Control Systems)": ["10.20.0.0/16", "192.168.20.0/24"],
|
|
"Level 3 (Site Operations)": ["10.30.0.0/16", "192.168.30.0/24"],
|
|
"Level 3.5 (DMZ)": ["172.16.0.0/16"],
|
|
"Level 4 (Enterprise)": ["10.0.0.0/16"],
|
|
}
|
|
|
|
|
|
def classify_purdue_level(ip_addr):
|
|
"""Classify an IP address to its Purdue Reference Model level."""
|
|
from ipaddress import ip_address, ip_network
|
|
|
|
addr = ip_address(ip_addr)
|
|
for level, subnets in PURDUE_LEVEL_RANGES.items():
|
|
for subnet in subnets:
|
|
if addr in ip_network(subnet):
|
|
return level
|
|
return "Unknown"
|
|
|
|
|
|
def analyze_ot_pcap(pcap_file):
|
|
"""Analyze pcap file to discover OT assets and communication patterns."""
|
|
packets = rdpcap(pcap_file)
|
|
|
|
assets = {}
|
|
connections = defaultdict(lambda: {"count": 0, "protocols": set(), "ports": set()})
|
|
protocol_stats = defaultdict(int)
|
|
cross_zone_flows = []
|
|
|
|
for pkt in packets:
|
|
if not pkt.haslayer(IP):
|
|
continue
|
|
|
|
src_ip = pkt[IP].src
|
|
dst_ip = pkt[IP].dst
|
|
|
|
# Track assets
|
|
for ip in (src_ip, dst_ip):
|
|
if ip not in assets:
|
|
assets[ip] = {
|
|
"ip": ip,
|
|
"purdue_level": classify_purdue_level(ip),
|
|
"protocols_observed": set(),
|
|
"roles": set(),
|
|
"first_seen": str(pkt.time),
|
|
"last_seen": str(pkt.time),
|
|
"mac": None,
|
|
}
|
|
assets[ip]["last_seen"] = str(pkt.time)
|
|
|
|
# Identify OT protocols by port
|
|
dst_port = None
|
|
if pkt.haslayer(TCP):
|
|
dst_port = pkt[TCP].dport
|
|
elif pkt.haslayer(UDP):
|
|
dst_port = pkt[UDP].dport
|
|
|
|
if dst_port and dst_port in OT_PROTOCOL_PORTS:
|
|
protocol_name = OT_PROTOCOL_PORTS[dst_port]
|
|
protocol_stats[protocol_name] += 1
|
|
assets[src_ip]["protocols_observed"].add(protocol_name)
|
|
assets[dst_ip]["protocols_observed"].add(protocol_name)
|
|
|
|
# Determine roles
|
|
assets[src_ip]["roles"].add("client/master")
|
|
assets[dst_ip]["roles"].add("server/slave")
|
|
|
|
# Track connections
|
|
conn_key = (src_ip, dst_ip)
|
|
connections[conn_key]["count"] += 1
|
|
if dst_port:
|
|
connections[conn_key]["ports"].add(dst_port)
|
|
if dst_port in OT_PROTOCOL_PORTS:
|
|
connections[conn_key]["protocols"].add(OT_PROTOCOL_PORTS[dst_port])
|
|
|
|
# Detect cross-zone communication
|
|
src_level = classify_purdue_level(src_ip)
|
|
dst_level = classify_purdue_level(dst_ip)
|
|
if src_level != dst_level and src_level != "Unknown" and dst_level != "Unknown":
|
|
cross_zone_flows.append({
|
|
"src": src_ip,
|
|
"src_level": src_level,
|
|
"dst": dst_ip,
|
|
"dst_level": dst_level,
|
|
"protocol": OT_PROTOCOL_PORTS.get(dst_port, f"port/{dst_port}"),
|
|
})
|
|
|
|
return {
|
|
"asset_count": len(assets),
|
|
"assets": {ip: {k: list(v) if isinstance(v, set) else v for k, v in info.items()} for ip, info in assets.items()},
|
|
"protocol_distribution": dict(protocol_stats),
|
|
"total_connections": len(connections),
|
|
"cross_zone_flows": cross_zone_flows[:50],
|
|
}
|
|
|
|
|
|
def generate_assessment_report(results):
|
|
"""Generate the OT network assessment findings report."""
|
|
report = []
|
|
report.append("=" * 70)
|
|
report.append("OT NETWORK PASSIVE DISCOVERY REPORT")
|
|
report.append(f"Generated: {datetime.now().isoformat()}")
|
|
report.append("=" * 70)
|
|
|
|
report.append(f"\nTotal Assets Discovered: {results['asset_count']}")
|
|
report.append(f"Total Unique Connections: {results['total_connections']}")
|
|
|
|
report.append("\n--- INDUSTRIAL PROTOCOL DISTRIBUTION ---")
|
|
for proto, count in sorted(results["protocol_distribution"].items(), key=lambda x: -x[1]):
|
|
report.append(f" {proto}: {count} packets")
|
|
|
|
report.append("\n--- CROSS-ZONE COMMUNICATION FLOWS ---")
|
|
if results["cross_zone_flows"]:
|
|
for flow in results["cross_zone_flows"][:20]:
|
|
report.append(
|
|
f" {flow['src']} ({flow['src_level']}) -> "
|
|
f"{flow['dst']} ({flow['dst_level']}) via {flow['protocol']}"
|
|
)
|
|
else:
|
|
report.append(" No cross-zone flows detected (check subnet classifications)")
|
|
|
|
report.append("\n--- FINDINGS ---")
|
|
# Check for Level 4 to Level 0-1 direct connections (critical finding)
|
|
for flow in results["cross_zone_flows"]:
|
|
if "Level 4" in flow["src_level"] and "Level 0-1" in flow["dst_level"]:
|
|
report.append(
|
|
f" [CRITICAL] Direct Enterprise-to-Field traffic: "
|
|
f"{flow['src']} -> {flow['dst']} via {flow['protocol']}"
|
|
)
|
|
elif "Level 4" in flow["src_level"] and "Level 2" in flow["dst_level"]:
|
|
report.append(
|
|
f" [HIGH] Enterprise-to-Control traffic bypassing DMZ: "
|
|
f"{flow['src']} -> {flow['dst']} via {flow['protocol']}"
|
|
)
|
|
|
|
return "\n".join(report)
|
|
|
|
|
|
if __name__ == "__main__":
|
|
if len(sys.argv) < 2:
|
|
print("Usage: python ot_network_discovery.py <pcap_file>")
|
|
sys.exit(1)
|
|
|
|
results = analyze_ot_pcap(sys.argv[1])
|
|
print(generate_assessment_report(results))
|
|
|
|
# Save detailed JSON
|
|
output_file = sys.argv[1].replace(".pcap", "_inventory.json")
|
|
with open(output_file, "w") as f:
|
|
json.dump(results, f, indent=2, default=str)
|
|
print(f"\nDetailed inventory saved to: {output_file}")
|
|
```
|
|
|
|
### Step 3: Evaluate Firewall Rules Between Purdue Zones
|
|
|
|
Analyze firewall configurations between OT zones to identify overly permissive rules, missing deny defaults, and unauthorized conduits that violate the IEC 62443 zone model.
|
|
|
|
```python
|
|
#!/usr/bin/env python3
|
|
"""OT Zone Firewall Rule Analyzer.
|
|
|
|
Parses firewall rule exports (CSV format) and evaluates them against
|
|
IEC 62443 zone/conduit model requirements.
|
|
"""
|
|
|
|
import csv
|
|
import json
|
|
import sys
|
|
from dataclasses import dataclass, field
|
|
from typing import Optional
|
|
|
|
|
|
@dataclass
|
|
class FirewallRule:
|
|
rule_id: str
|
|
source_zone: str
|
|
source_ip: str
|
|
dest_zone: str
|
|
dest_ip: str
|
|
service: str
|
|
port: str
|
|
action: str
|
|
enabled: bool
|
|
comment: str = ""
|
|
|
|
|
|
# IEC 62443 zone communication policy
|
|
# Defines which zone pairs are allowed to communicate and through what conduit
|
|
ALLOWED_CONDUITS = {
|
|
("Level 4", "Level 3.5"): {
|
|
"allowed_ports": [443, 3389, 22],
|
|
"description": "Enterprise to DMZ - web services, jump hosts",
|
|
"requires_inspection": True,
|
|
},
|
|
("Level 3.5", "Level 3"): {
|
|
"allowed_ports": [443, 1433, 5432, 8080],
|
|
"description": "DMZ to Site Ops - historian mirror, OPC relay",
|
|
"requires_inspection": True,
|
|
},
|
|
("Level 3", "Level 2"): {
|
|
"allowed_ports": [502, 44818, 4840, 102],
|
|
"description": "Site Ops to Control - OPC UA, Modbus, S7comm",
|
|
"requires_inspection": True,
|
|
},
|
|
("Level 2", "Level 1"): {
|
|
"allowed_ports": [502, 44818, 102, 2222],
|
|
"description": "Control to Field - direct industrial protocols",
|
|
"requires_inspection": False,
|
|
},
|
|
}
|
|
|
|
# Prohibited direct connections
|
|
PROHIBITED_CONDUITS = [
|
|
("Level 4", "Level 3"),
|
|
("Level 4", "Level 2"),
|
|
("Level 4", "Level 1"),
|
|
("Level 4", "Level 0"),
|
|
("Level 3", "Level 1"),
|
|
("Level 3", "Level 0"),
|
|
("Internet", "Level 3.5"),
|
|
("Internet", "Level 3"),
|
|
("Internet", "Level 2"),
|
|
("Internet", "Level 1"),
|
|
]
|
|
|
|
|
|
def parse_firewall_rules(csv_file):
|
|
"""Parse firewall rules from CSV export."""
|
|
rules = []
|
|
with open(csv_file, "r") as f:
|
|
reader = csv.DictReader(f)
|
|
for row in reader:
|
|
rules.append(FirewallRule(
|
|
rule_id=row.get("rule_id", ""),
|
|
source_zone=row.get("source_zone", ""),
|
|
source_ip=row.get("source_ip", ""),
|
|
dest_zone=row.get("dest_zone", ""),
|
|
dest_ip=row.get("dest_ip", ""),
|
|
service=row.get("service", ""),
|
|
port=row.get("port", ""),
|
|
action=row.get("action", ""),
|
|
enabled=row.get("enabled", "true").lower() == "true",
|
|
comment=row.get("comment", ""),
|
|
))
|
|
return rules
|
|
|
|
|
|
def analyze_rules(rules):
|
|
"""Analyze firewall rules against IEC 62443 zone model."""
|
|
findings = {"critical": [], "high": [], "medium": [], "low": [], "info": []}
|
|
|
|
for rule in rules:
|
|
if not rule.enabled or rule.action.lower() != "allow":
|
|
continue
|
|
|
|
zone_pair = (rule.source_zone, rule.dest_zone)
|
|
port = int(rule.port) if rule.port.isdigit() else 0
|
|
|
|
# Check for prohibited conduits
|
|
if zone_pair in PROHIBITED_CONDUITS:
|
|
findings["critical"].append({
|
|
"rule_id": rule.rule_id,
|
|
"finding": f"Prohibited direct connection: {rule.source_zone} -> {rule.dest_zone}",
|
|
"detail": f"Rule allows {rule.source_ip} to reach {rule.dest_ip}:{rule.port} ({rule.service})",
|
|
"remediation": "Remove rule. Route traffic through DMZ (Level 3.5) with application-layer inspection.",
|
|
})
|
|
|
|
# Check for overly broad rules (any/any)
|
|
elif rule.source_ip in ("any", "0.0.0.0/0") or rule.dest_ip in ("any", "0.0.0.0/0"):
|
|
findings["high"].append({
|
|
"rule_id": rule.rule_id,
|
|
"finding": f"Overly permissive rule with 'any' address",
|
|
"detail": f"{rule.source_ip} -> {rule.dest_ip}:{rule.port} in {zone_pair}",
|
|
"remediation": "Restrict to specific host IPs per IEC 62443 least-privilege conduit policy.",
|
|
})
|
|
|
|
# Check allowed conduits for port violations
|
|
elif zone_pair in ALLOWED_CONDUITS:
|
|
conduit = ALLOWED_CONDUITS[zone_pair]
|
|
if port and port not in conduit["allowed_ports"]:
|
|
findings["medium"].append({
|
|
"rule_id": rule.rule_id,
|
|
"finding": f"Unauthorized port in conduit {zone_pair}",
|
|
"detail": f"Port {port} ({rule.service}) not in allowed list {conduit['allowed_ports']}",
|
|
"remediation": f"Remove port {port} from conduit or justify in risk assessment.",
|
|
})
|
|
|
|
return findings
|
|
|
|
|
|
if __name__ == "__main__":
|
|
if len(sys.argv) < 2:
|
|
print("Usage: python ot_firewall_analyzer.py <rules.csv>")
|
|
sys.exit(1)
|
|
|
|
rules = parse_firewall_rules(sys.argv[1])
|
|
findings = analyze_rules(rules)
|
|
|
|
print("=" * 70)
|
|
print("OT ZONE FIREWALL RULE ANALYSIS")
|
|
print("=" * 70)
|
|
for severity in ["critical", "high", "medium", "low"]:
|
|
if findings[severity]:
|
|
print(f"\n--- {severity.upper()} FINDINGS ({len(findings[severity])}) ---")
|
|
for f in findings[severity]:
|
|
print(f" [{f['rule_id']}] {f['finding']}")
|
|
print(f" Detail: {f['detail']}")
|
|
print(f" Fix: {f['remediation']}")
|
|
```
|
|
|
|
### Step 4: Assess Industrial Protocol Security
|
|
|
|
Evaluate the security configuration of industrial protocols in use, checking for authentication, encryption, and access controls.
|
|
|
|
```bash
|
|
# Capture Modbus/TCP traffic for analysis
|
|
tcpdump -i eth0 -w ot_capture.pcap 'port 502 or port 44818 or port 4840 or port 102 or port 20000' -c 100000
|
|
|
|
# Use Wireshark with OT protocol dissectors for deep inspection
|
|
tshark -r ot_capture.pcap -Y "modbus" -T fields \
|
|
-e ip.src -e ip.dst -e modbus.func_code -e modbus.reference_num \
|
|
-e modbus.word_cnt > modbus_analysis.csv
|
|
|
|
# Check for unauthenticated Modbus write operations (function codes 5,6,15,16)
|
|
tshark -r ot_capture.pcap -Y "modbus.func_code >= 5 && modbus.func_code <= 16" \
|
|
-T fields -e ip.src -e ip.dst -e modbus.func_code -e frame.time
|
|
|
|
# Scan for OPC UA servers and check security policies
|
|
# Only run against Level 3+ systems with explicit authorization
|
|
python3 -c "
|
|
from opcua import Client
|
|
server_url = 'opc.tcp://10.30.1.50:4840'
|
|
client = Client(server_url)
|
|
endpoints = client.connect_and_get_server_endpoints()
|
|
for ep in endpoints:
|
|
print(f'Endpoint: {ep.EndpointUrl}')
|
|
print(f' Security Mode: {ep.SecurityMode}')
|
|
print(f' Security Policy: {ep.SecurityPolicyUri}')
|
|
print(f' Auth Tokens: {[t.TokenType for t in ep.UserIdentityTokens]}')
|
|
"
|
|
```
|
|
|
|
### Step 5: Generate Assessment Report
|
|
|
|
Compile findings into a structured report aligned with IEC 62443 and NIST SP 800-82 Rev.3.
|
|
|
|
```
|
|
OT Network Security Assessment Report
|
|
=======================================
|
|
Facility: Chemical Processing Plant - Site Alpha
|
|
Assessment Date: 2026-02-23
|
|
Standard: IEC 62443-3-3 / NIST SP 800-82r3
|
|
Assessor: [Assessor Name]
|
|
|
|
EXECUTIVE SUMMARY:
|
|
The OT network assessment identified 47 assets across Purdue levels 0-4.
|
|
12 critical and 23 high-severity findings were identified, primarily
|
|
related to insufficient network segmentation, unauthenticated industrial
|
|
protocols, and unauthorized cross-zone communication paths.
|
|
|
|
ASSET INVENTORY SUMMARY:
|
|
Level 0-1 (Field): 18 devices (PLCs, RTUs, I/O modules)
|
|
Level 2 (Control): 9 devices (HMIs, engineering workstations)
|
|
Level 3 (Operations): 12 devices (historians, OPC servers, app servers)
|
|
Level 3.5 (DMZ): 3 devices (data diode, jump server, patch server)
|
|
Level 4 (Enterprise): 5 devices (domain controllers, file servers)
|
|
|
|
CRITICAL FINDINGS:
|
|
[OT-001] Direct Enterprise-to-PLC communication detected
|
|
Source: 10.0.5.22 (Level 4 - IT workstation)
|
|
Dest: 10.10.1.15 (Level 1 - Allen-Bradley PLC)
|
|
Protocol: EtherNet/IP (port 44818)
|
|
Impact: An attacker on the corporate network could directly modify PLC logic
|
|
Remediation: Block direct L4-L1 traffic; route through DMZ proxy
|
|
|
|
[OT-002] Modbus/TCP write commands without authentication
|
|
Affected: 8 PLCs accepting unauthenticated FC6 (Write Single Register)
|
|
Impact: Any device on the OT network can modify process setpoints
|
|
Remediation: Deploy Modbus-aware firewall; restrict write-capable sources
|
|
|
|
[OT-003] Flat network - no segmentation between Purdue levels
|
|
Detail: All OT devices share VLAN 100 (10.10.0.0/16)
|
|
Impact: Compromised HMI has direct access to all PLCs and SIS
|
|
Remediation: Implement zone-based segmentation per IEC 62443-3-2
|
|
|
|
RISK MATRIX:
|
|
Critical: 12 findings (immediate remediation required)
|
|
High: 23 findings (remediate within 30 days)
|
|
Medium: 15 findings (remediate within 90 days)
|
|
Low: 8 findings (remediate in next maintenance cycle)
|
|
```
|
|
|
|
## Key Concepts
|
|
|
|
| Term | Definition |
|
|
|------|------------|
|
|
| Purdue Reference Model | Hierarchical architecture model (Levels 0-5) for organizing industrial control systems, defining security zones from physical process to enterprise IT |
|
|
| IEC 62443 | International standard series for industrial automation and control systems (IACS) security, defining security levels, zones, conduits, and security requirements |
|
|
| Zone | A grouping of logical or physical assets that share common security requirements, defined by IEC 62443-3-2 |
|
|
| Conduit | A logical grouping of communication channels connecting two or more zones, subject to common security policies |
|
|
| SCADA | Supervisory Control and Data Acquisition - system architecture for high-level process supervisory management of industrial processes |
|
|
| DCS | Distributed Control System - control system architecture where control elements are distributed throughout the system |
|
|
| Air Gap | Physical isolation of OT networks from IT/internet, increasingly replaced by managed conduits with firewalls and data diodes |
|
|
| Safety Instrumented System (SIS) | Independent system designed to bring a process to a safe state when a hazardous condition is detected |
|
|
|
|
## Tools & Systems
|
|
|
|
- **Nozomi Networks Guardian**: Passive OT network monitoring platform providing asset discovery, vulnerability assessment, and anomaly detection for industrial environments
|
|
- **Dragos Platform**: OT cybersecurity platform with asset visibility, threat detection, and vulnerability management designed for critical infrastructure
|
|
- **Claroty xDome**: Cyber-physical systems protection platform providing comprehensive asset inventory and risk scoring across OT, IoT, and IIoT
|
|
- **Wireshark/tshark**: Network protocol analyzer with industrial protocol dissectors for Modbus, DNP3, S7comm, EtherNet/IP, OPC UA, and BACnet
|
|
- **Nmap with OT scripts**: Network scanner with NSE scripts for OT protocol enumeration (use only on Level 2+ with authorization)
|
|
- **Grassmarlin**: NSA-developed passive OT network mapping tool for identifying SCADA/ICS network topology
|
|
|
|
## Common Scenarios
|
|
|
|
### Scenario: Flat OT Network with No Segmentation
|
|
|
|
**Context**: A water utility has all OT devices on a single VLAN. Passive network monitoring reveals HMIs, PLCs, historians, and a domain controller all sharing the same Layer 2 broadcast domain. There is no DMZ between the corporate network and the OT environment.
|
|
|
|
**Approach**:
|
|
1. Deploy passive monitoring on the SPAN port to capture a complete communication baseline over 2-4 weeks
|
|
2. Map all device-to-device communication flows with protocols and data volumes
|
|
3. Classify assets into Purdue levels based on their function and communication patterns
|
|
4. Design zone architecture with VLANs and inter-zone firewalls per IEC 62443-3-2
|
|
5. Prioritize DMZ creation between Level 3 and Level 4 as the highest-impact segmentation
|
|
6. Present segmentation plan with migration phases that avoid production disruption
|
|
|
|
**Pitfalls**: Active scanning PLCs during production can cause communication timeouts and process disruptions. Implementing segmentation without a complete traffic baseline will break legitimate control system communications. Relying solely on network-layer firewalls without industrial protocol inspection leaves Modbus/TCP and EtherNet/IP write commands unchecked.
|
|
|
|
## Output Format
|
|
|
|
```
|
|
OT Network Security Assessment Report
|
|
=======================================
|
|
Facility: [Facility Name]
|
|
Assessment Date: YYYY-MM-DD
|
|
Standard: IEC 62443-3-3 / NIST SP 800-82r3
|
|
|
|
EXECUTIVE SUMMARY:
|
|
[2-3 sentence overview of findings and risk level]
|
|
|
|
ASSET INVENTORY:
|
|
Level 0-1: [count] field devices
|
|
Level 2: [count] control systems
|
|
Level 3: [count] operations systems
|
|
Level 3.5: [count] DMZ systems
|
|
Level 4: [count] enterprise systems
|
|
|
|
FINDINGS BY SEVERITY:
|
|
Critical: [count] (immediate action required)
|
|
High: [count] (30-day remediation)
|
|
Medium: [count] (90-day remediation)
|
|
Low: [count] (next maintenance window)
|
|
|
|
DETAILED FINDINGS:
|
|
[OT-NNN] Finding Title
|
|
Severity: Critical|High|Medium|Low
|
|
Affected Assets: [list]
|
|
IEC 62443 Reference: [section]
|
|
NIST 800-82r3 Reference: [section]
|
|
Description: [technical detail]
|
|
Impact: [operational and safety impact]
|
|
Remediation: [specific technical remediation steps]
|
|
```
|